MedicalRegsdotCom banner
MedicalRegsdotCom avatar
MedicalRegsdotCom
@medicalregsdotcom606
订阅数27
总播放2626
视频数28
MedicalRegsdotCom发布于 2020年2月22日 23:201:56
TIPS for Designing to IEC 60601-1-11.  By:  MedicalRegs.com thumbnail

TIPS for Designing to IEC 60601-1-11. By: MedicalRegs.com

6年前长尾期
tipsfordesigningiec60601tips designing iec
发布时间
2020年2月22日 23:20
视频时长
1:56
视频类型
-
频道地区
-
发布时间判断
发布时间判断数据不足
当前频道还缺少完整的历史发布时间模式,建议继续累积频道数据后再观察最佳时段命中情况。
商业化判断
暂无明确商业化标签
当前视频更适合从播放增速、互动质量和同主题竞争情况来判断后续变现空间。
动作建议
优先观察持续增长能力
当前视频基础条件较完整,建议继续观察近7日播放和收入是否稳定抬升,再决定是否扩写成系列内容。
播放量
237
点赞数
2
评论数
0
日预估收入
-
累计预估收入
$0.14 - $0.83
RPM 区间
$0.6 - $3.5
1日涨播放
0
7日涨播放
0
1日涨点赞
0
7日涨点赞
0
1日涨评论
0
7日涨评论
0
速度分
0%
主题聚类
tips
视频说明
TIPS For Designing Medical Devices For Home Healthcare. Some Key Areas To Consider… The collateral safety standard that applies to active medical devices is, IEC 60601-1-11. The standard was developed because, it is expected that the home environment is less controlled compared to a professional healthcare facility. A professional healthcare environment has stable ambient temperature and humidity. A professional healthcare environment has reliable protective earth system. In contrast, residential homes have unreliable PE system. Rusted and loose PE terminals = High impedance = High earth leakage current With this in mind, additional or new risks may be introduced with the use of your medical device in a home environment. In your risk assessment and design inputs, you should consider the following: Class 2 Design The user is protected from electric shock by double or reinforced insulation. Is the user of your device also the patient? If so, your IFU should reflect this. Make sure it is written in layman's terms. Validate your IFU based on user/patient profile. Consider accessibility to hazardous live and moving parts – In a home environment your device may be exposed to children too. Enclosure openings must pass accessibility test finger probe/pin. Consider electromagnetic interference in home environment. Your device will be bombarded with electromagnetic interference radiated from electronic gadgets, kitchen appliances, etc. Design for optimal immunity. Consider Ingress Protection (IP) rating. Is the device body worn? Stationary? Transportable or mobile? If it's body worn as an example, the user/patient may forget and shower or wash the dishes while the device is worn. Include this in the risk assessment. Consider strangulation & trip hazards Balance length of tubings and interconnecting cables design with associated hazards. Consider temperature, humidity, and altitude. What is the worst-case home environmental conditions can you expect based on your geographical markets? Clarity MedicalRegs.com
同主题推荐
围绕当前主题继续看高相关视频,帮助判断选题空间和内容形态。
主题:tips
暂无足够的同主题视频数据。
视频常见问题

以下问题重点解释这条视频能看什么、收益为何是估算值,以及如何把它用于内容研究与竞品分析。

这个视频页能看出什么?

你可以查看播放、点赞、评论、RPM 与收益估算、发布时间、主题标签、相关视频以及所属频道背景,用来判断内容表现和后续选题方向。

为什么 RPM 和收益只是估算值?

实际收入会受到广告填充率、受众地区、季节性、广告主需求与是否开启变现等因素影响,因此页面给出的数字更适合做趋势判断和横向比较。

怎么用这个视频页做内容研究?

建议结合发布时间、主题标签、相关视频与频道历史内容,观察什么题材、节奏和发布窗口更容易拿到播放与商业化表现。